Type: | Insulated |
---|---|
Conductor Type: | Solid Strand |
Application: | Overhead |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ONE-STOP SOLUTIONS FOR WIRES&CABLES - HENAN UME CABLE CO., LTD
Over 30 years of Wires and Cables manufacture experience and Export to over 50 countries.
1. Applications
Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
2. Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene Insulation, concentric strand AAC, ACSR, OR 6201 alloy neutral messenger.
3. Standard
ASTM B-230, B-231, B-232 and B-399, IECA S-76-474
Code Word |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000ft.(Ibs.) |
Allowable Ampacities+ |
||||||
Size (AWG) |
Stranding | Insul. Thick. (mils) |
Size (kcmil) |
Stranding | Rated Strength (Ibs.) |
XLP | POLY | XLP | POLY | |
AAC NEUTRAL-MESSENGER | ||||||||||
Patella | 6 | 7 | 45 | 6 | 7 | 563 | 103 | 103 | 85 | 70 |
Oyster | 4 | 7 | 45 | 4 | 7 | 881 | 154 | 154 | 115 | 90 |
Clam | 2 | 7 | 45 | 2 | 7 | 1350 | 233 | 233 | 150 | 120 |
Murex | 1/0 | 7 | 60 | 1/0 | 7 | 1990 | 374 | 374 | 205 | 160 |
Purpura | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 368 | 368 | 205 | 160 |
Nassa | 2/0 | 7 | 60 | 2/0 | 7 | 2510 | 462 | 462 | 235 | 185 |
Melita | 3/0 | 17 | 60 | 3/0 | 19 | 3310 | 562 | 562 | 275 | 215 |
Portunus | 4/0 | 18 | 60 | 4/0 | 19 | 4020 | 696 | 696 | 315 | 245 |
Nannynose | 336.4 | 19 | 80 | 336.4 | 19 | 6146 | 1118 | 1118 | 420 | 325 |
+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2ft./sec. wind in sun. |
Code Word |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000ft.(Ibs.) |
Allowable Ampacities+ |
|||||||
Size (AWG) |
Stranding | Insul. Thick. (mils) |
Equiv. Dia. (AWG)++ |
Size (kcmil) |
Stranding | Rated Strength (Ibs.) |
XLP | POLY | XLP | POLY | |
6201 ALLOY NEUTRAL-MESSENGER | |||||||||||
Minex | 6 | 1 | 45 | 6 | 30.58 | 7 | 1110 | 101 | 101 | 85 | 70 |
Hippa | 6 | 7 | 45 | 6 | 30.58 | 7 | 1110 | 107 | 107 | 85 | 70 |
Prawn | 4 | 1 | 45 | 4 | 48.69 | 7 | 1760 | 152 | 152 | 115 | 90 |
Barnacle | 4 | 7 | 45 | 4 | 48.69 | 7 | 1760 | 160 | 160 | 115 | 90 |
Shrimp | 2 | 7 | 45 | 2 | 77.47 | 7 | 2800 | 243 | 243 | 150 | 120 |
Gammarus | 1/0 | 7 | 60 | 1/0 | 123.3 | 7 | 4460 | 390 | 390 | 205 | 160 |
Leda | 1/0 | 9 | 60 | 1/0 | 123.3 | 7 | 4460 | 384 | 384 | 205 | 160 |
Dungenese | 2/0 | 7 | 60 | 2/0 | 155.4 | 7 | 5390 | 483 | 483 | 235 | 185 |
Cyclops | 2/0 | 11 | 60 | 2/0 | 155.4 | 7 | 5390 | 474 | 474 | 235 | 185 |
Flustra | 3/0 | 17 | 60 | 3/0 | 195.7 | 7 | 6790 | 587 | 587 | 275 | 215 |
Lepas | 4/0 | 18 | 60 | 4/0 | 246.9 | 7 | 8560 | 728 | 728 | 315 | 245 |
Code Word |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000ft.(Ibs.) |
Allowable Ampacities+ |
|||||||
Size (AWG) |
Stranding | Insul. Thick. (mils) |
Equiv. Dia. (AWG)++ |
Size (kcmil) |
Stranding | Rated Strength (Ibs.) |
XLP | POLY | XLP | POLY | |
6201 ALLOY REDUCED NEUTRAL-MESSENGER | |||||||||||
Artemia | 4 | 1 | 45 | 6 | 30.58 | 7 | 1110 | 135 | 135 | 115 | 90 |
Crab | 4 | 7 | 45 | 6 | 30.58 | 7 | 1110 | 143 | 143 | 115 | 90 |
Solaster | 2 | 7 | 45 | 4 | 48.69 | 7 | 1760 | 216 | 216 | 150 | 120 |
Sandcrab | 1/0 | 7 | 60 | 2 | 77.47 | 7 | 2800 | 347 | 347 | 205 | 160 |
Echinus | 1/0 | 9 | 60 | 2 | 77.47 | 7 | 2800 | 341 | 341 | 205 | 160 |
Fulgar | 3/0 | 17 | 60 | 1/0 | 123.3 | 7 | 4460 | 519 | 519 | 275 | 215 |
Arca | 4/0 | 18 | 60 | 2/0 | 155.4 | 7 | 5390 | 643 | 643 | 315 | 245 |
Code Word |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000ft.(Ibs.) |
Allowable Ampacities+ |
||||||
Size (AWG) |
Stranding | Insul. Thick. (mils) |
Size (kcmil) |
Stranding | Rated Strength (Ibs.) |
XLP | POLY | XLP | POLY | |
ACSR NEUTRAL-MESSENGER | ||||||||||
Paludina | 6 | 1 | 45 | 6 | 43252 | 1190 | 109 | 109 | 85 | 70 |
Voluta | 6 | 7 | 45 | 6 | 43252 | 1190 | 114 | 114 | 85 | 70 |
Whelk | 4 | 1 | 45 | 4 | 43252 | 1860 | -- | 164 | 115 | 90 |
Periwinkle | 4 | 7 | 45 | 4 | 43252 | 1860 | 172 | 172 | 115 | 90 |
Conch | 2 | 7 | 45 | 2 | 43252 | 2850 | 262 | 262 | 150 | 120 |
Neritina | 1/0 | 7 | 60 | 1/0 | 43252 | 4380 | 420 | 420 | 205 | 160 |
Cenia | 1/0 | 9 | 60 | 1/0 | 43252 | 4380 | 414 | 414 | 205 | 160 |
Runcina | 2/0 | 7 | 60 | 2/0 | 43252 | 5310 | 520 | 520 | 235 | 185 |
Triton | 2/0 | 11 | 60 | 2/0 | 43252 | 5310 | 512 | 512 | 235 | 185 |
Mursia | 3/0 | 17 | 60 | 3/0 | 43252 | 6620 | 635 | 635 | 275 | 215 |
Zuzara | 4/0 | 18 | 60 | 4/0 | 43252 | 8350 | 789 | 789 | 315 | 245 |
Limpet | 336.4 | 19 | 80 | 336.4 | 43118 | 8680 | 1167 | 1167 | 420 | 325 |
Code Word |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000ft.(Ibs.) |
Allowable Ampacities+ |
||||||
Size (AWG) |
Stranding | Insul. Thick. (mils) |
Size (kcmil) |
Stranding | Rated Strength (Ibs.) |
XLP | POLY | XLP | POLY | |
ACSR REDUCED NEUTRAL-MESSENGER | ||||||||||
Scallop | 4 | 1 | 45 | 6 | 43252 | 1190 | -- | 142 | 115 | 90 |
Strombus | 4 | 7 | 45 | 6 | 43252 | 1190 | 151 | 151 | 115 | 90 |
Cockle | 2 | 7 | 45 | 4 | 43252 | 1860 | 228 | 228 | 150 | 120 |
Janthina | 1/0 | 7 | 60 | 2 | 43252 | 2853 | 366 | 366 | 205 | 160 |
Ranella | 1/0 | 9 | 60 | 2 | 43252 | 2853 | 360 | 360 | 205 | 160 |
Cavolinia | 2/0 | 7 | 60 | 1 | 43252 | 3550 | 453 | 453 | 235 | 185 |
Clio | 2/0 | 11 | 60 | 1 | 43252 | 3550 | 444 | 444 | 235 | 185 |
Aega | 3/0 | 17 | 60 | 1/0 | 43252 | 4380 | 549 | 549 | 275 | 215 |
Cerapus | 4/0 | 18 | 60 | 2/0 | 43252 | 5310 | 681 | 681 | 315 | 245 |
HENAN UME CABLE CO., LTD has a strict quality control policy in every step from the order to After-sales service!
Production:
Q1: Are you a manufacturer?
Yes, we are the manufacturer.
Q2: What are your main products?
Our products range as follows:
1. Electrical wire/PVC Building Wires.
2. PVC/XLPE insulated Power Cables up to 110kv.
3. Overhead Aerial Bundle Cable/ABC Cables.
4. Bare Conductors, like AAC, AAAC, ACSR, ACAR, ASCR/AW, and so on.
5. Steel wire/strand-like EHS, GSW and ACS(Aluminum Clad Steel), CCS(Copper Clad Steel).
6. Rubber Cables, Mining Cables, Welding Cable, and Control Cables.
7. Concentric Cables with Copper/Aluminum/Aluminum Alloy 8000s' Conductor.
Q3: Do you provide samples? Is it free or extra?
Yes, we could offer the samples for free
Q4: Is the quality of your products guaranteed?
We have passed ISO9001, ISO14001, ISO45001, and all our products have CE certificates.
Q5: Which markets do you involve mainly in?
Our products have been exported mainly to Africa, the Middle East, Southeast Asia, South America, Central America, North America, Europe, Australia, etc.
Q6: What is your payment term?
T/T or L/C
Q7: What about the delivery time?
Generally, it is 3-7days if the goods are in stock. Or it is 7-30days if the goods are not in stock, it is according to quantity.