Copper Clad Steel Wire High Conductivity Overhead Transmission Lines CCS

Product Details
Type: Bare
Conductor Type: Solid Strand
Application: Overhead
Still deciding? Get samples of US$ 1/Piece
Request Sample
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Copper Clad Steel Wire High Conductivity Overhead Transmission Lines CCS
  • Copper Clad Steel Wire High Conductivity Overhead Transmission Lines CCS
  • Copper Clad Steel Wire High Conductivity Overhead Transmission Lines CCS
  • Copper Clad Steel Wire High Conductivity Overhead Transmission Lines CCS
  • Copper Clad Steel Wire High Conductivity Overhead Transmission Lines CCS
  • Copper Clad Steel Wire High Conductivity Overhead Transmission Lines CCS
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • TESTING
  • Certifications
  • Packaging & Shipping
  • Customer Visit
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
Copper Clad Steel Wire CCS
Conductor Material
Copper Clad Steel
Sheath Material
None
Insulation Material
None
Material Shape
Round Wire
Range of Application
Overhead
Certification
ISO9001, CE, SGS TUV
Brand
UME
Third Party Inspection
Accepted
Sample
Free
Color
Customer Specified
OEM
Accepted
Transport Package
Drum
Specification
Copper Clad Steel Wire
Trademark
UME
Origin
China
HS Code
7413000000
Production Capacity
500, 000km Per Month

Product Description

Product Description

ONE-STOP SOLUTIONS FOR WIRES&CABLES - HENAN UME CABLE CO., LTD
Over 30 years of Wires and Cables manufacture experience and Export to over 50 countries.

Copper Clad Steel Wire High Conductivity Overhead Transmission Lines CCS
Copper Clad Steel Wire High Conductivity Overhead Transmission Lines CCS



1. Applications
It is mainly used for grounding purposes, line tracing to locate underground utilities, drop wire of telephone cables, and inner conductor of coaxial cables, including thin hookup cables like RG-174 and CATV cable. It is also used in some antennas for RF conducting wires.

2. Construction
Copper clad steel wire CCS combines the high tensile strength of steel as its core and the conductivity properties of copper as its outer layer. The core material is usually low carbon steel and is typically used as either grounding wire or the inner conductor of coaxial cables.

3. Standards
30% conductivity
40% conductivity

Product Parameters

 

Size (AWG) Diameter (Inches) Area (cir. mils) Feet Per Pound Pounds Per 1000 FT Ohms Per 1000 FT at 20ºC Size (AWG)
      10% CCA 15% CCA 10% CCA 15% CCA 10% CCA 15% CCA  
14 0.0641 4109 215 197 4.64 5.06 3.91 3.79 14
15 0.0571 3260 270 247 3.69 4.03 4.93 4.78 15
16 0.0508 2581 342 314 2.92 3.19 6.23 6.05 16
17 0.0453 2052 430 394 2.32 2.53 7.83 7.6 17
18 0.0403 1624 542 497 1.84 2.01 9.9 9.61 18
19 0.0359 1289 684 627 1.46 1.59 12.5 12.1 19
20 0.032 1024 862 791 1.16 1.26 15.7 15.2 20
21 0.0285 812.3 1087 997 0.92 1 19.8 19.2 21
22 0.0253 640.1 1378 1264 0.726 0.792 25.1 24.4 22
23 0.0226 510.8 1728 1585 0.58 0.632 31.5 30.5 23
24 0.0201 404 2184 2004 0.456 0.498 39.8 38.6 24
25 0.0179 320.4 2750 2524 0.363 0.396 50.2 48.7 25
26 0.0159 252.8 3498 3210 0.286 0.312 63.6 61.7 26
27 0.0142 201.6 4378 4018 0.228 0.249 79.7 77.3 27
28 0.0126 158.8 5554 5096 0.18 0.196 101 98.2 28
29 0.0113 127.7 6915 6346 0.145 0.158 126 122 29
30 0.01 100 8811 8085 0.113 0.124 161 156 30
31 0.0089 79.21 11134 10216 0.0896 0.0979 203 197 31
32 0.008 64 13777 12642 0.0726 0.0792 251 244 32
33 0.0071 50.41 17488 0.16048 0.0572 0.0624 319 310 33
34 0.0063 39.69 22214 20384 0.0449 0.049 405 390 34
35 0.0056 31.36 28035 25725 0.0355 0.0387 513 498 35
36 0.005 25 35244 32340 0.0283 0.0309 643 624 36
37 0.0045 20.25 43521 39935 0.0229 0.025 794 770 37
38 0.004 16 55002 50470 0.0181 0.0196 1000 975 38
39 0.0035 12.25 72090 66150 0.0139 0.0151 1310 1280 39
40 0.0031 9.61 91848 84280 0.0109 0.0119 1670 1620 40
 
Cross-section area ( mm2) Single Wire Diameter( mm ) Nos Outer Diameter( mm ) Reference Weight (kg/km )
16 1.7 7 5.1 130
25 2.12 7 6.36 200
35 2.52 7 7.5 280
50 3 7 9 410
70 3.5 7 10.6 590
95 2.52 19 12.6 780
120 2.8 19 14 980
150 3.15 19 15.8 1230
185 3.5 19 17.5 1520
240 4 19 20 1970
300 3.15 37 23.5 2460
400 3.7 37   3280
30% Conductivity
Conductor Conductor Size
 AWG
Overall Dia. Min. Breaking Loads Weight Cross Section Area I2t Approx. Short-time
Fusing Current  at 30 Cycles
 (kA)
Nominal DC  
Resistance at 68°F
(
Ω/KFT)
Wire No. AWG inch mm lbf kN lbs/kft kg/km cmil mm2 kA2s
1 2 No. 2 0.258  6.54  2276 10.10  184.1 274.04  66368 33.63  30.26  7.78  0.5209 
1 4 No. 4 0.204  5.19  1431 6.40  115.8 172.34  41738 21.15  11.97  4.89  0.8283 
1 6 No. 6 0.162  4.12  900 4.00  72.8 108.39  26250 13.30  4.73  3.08  1.3169 
3 4 3 No. 4 0.440  11.18  4079 18.10  350.2 521.17  125215 63.45  107.73  14.68  0.2761 
3 5 3 No. 5 0.392  9.96  3234 14.40  277.6 413.15  99263 50.30  67.70  11.64  0.3483 
3 6 3 No. 6 0.349  8.87  2565 11.40  220.2 327.70  78732 39.89  42.59  9.23  0.4391 
3 7 3 No. 7 0.311  7.90  2035 9.10  174.7 260.00  62467 31.65  26.81  7.32  0.5534 
3 8 3 No. 8 0.277  7.03  1614 7.20  138.5 206.18  49537 25.10  16.86  5.81  0.6979 
3 9 3 No. 9 0.247  6.26  1279 5.70  109.8 163.42  39262 19.89  10.59  4.60  0.8805 
3 10 3 No. 10 0.220  5.58  1015 4.50  87.1 129.66  31151 15.78  6.67  3.65  1.1098 
3 12 3 No. 12 0.174  4.42  638 2.80  54.8 81.52  19586 9.92  2.64  2.30  1.7650 
7 4 7 No. 4 0.613  15.57  9017 40.10  818.8 1218.48  292169 148.04  586.53  34.25  0.1183 
7 5 7 No. 5 0.546  13.86  7148 31.80  649.1 965.93  231613 117.36  368.59  27.15  0.1493 
7 6 7 No. 6 0.486  12.34  5670 25.20  514.8 766.15  183708 93.09  231.89  21.54  0.1882 
7 7 7 No. 7 0.433  11.00  4498 20.00  408.5 607.87  145757 73.86  145.98  17.09  0.2372 
7 8 7 No. 8 0.386  9.79  3567 15.90  323.9 482.04  115586 58.57  91.80  13.55  0.2991 
7 9 7 No. 9 0.343  8.72  2827 12.60  256.7 382.06  91612 46.42  57.67  10.74  0.3774 
7 10 7 No. 10 0.306  7.76  2243 10.00  203.7 303.13  72685 36.83  36.30  8.52  0.4756 
19 5 19 No. 5 0.910  23.10  19402 86.30  1768.7 2632.20  628665 318.55  2715.55  73.70  0.0550 
19 6 19 No. 6 0.810  20.57  15389 68.50  1402.9 2087.77  498636 252.66  1708.39  58.45  0.0693 
19 7 19 No. 7 0.722  18.33  12210 54.30  1113.1 1656.48  395627 200.47  1075.46  46.38  0.0874 
19 8 19 No. 8 0.643  16.32  9682 43.10  882.7 1313.59  313733 158.97  676.30  36.78  0.1102 
19 9 19 No. 9 0.572  14.53  7674 34.10  699.6 1041.13  248660 126.00  424.85  29.15  0.1390 
40% Conductivity 
Conductor Conductor Size
AWG
Overall Dia. Min. Breaking Loads Weight Cross Section Area I2t Approx. Short-time Fusing Current at
30 Cycles (kA)
Nominal DC  
Resistance at 68°F
(
Ω/KFT)
Wire No. AWG inch mm lbf kN lbs/kft kg/km cmil mm2 kA2s
1 2 No. 2 0.258 6.54  2023 9.0  186.1  276.94 66368 33.63 40.29  8.98  0.3907 
1 4 No. 4 0.204 5.19  1272 5.7  117.0  174.16 41738 21.15 15.94  5.65  0.6212 
1 6 No. 6 0.162 4.12  800 3.6  73.6  109.54 26250 13.3 6.30  3.55  0.9877 
3 4 3 No. 4 0.44 11.18  3626 16.1  353.9  526.67 125215 63.45 143.43  16.94  0.2087 
3 5 3 No. 5 0.392 9.96  2874 12.8  280.5  417.51 99263 50.3 90.13  13.43  0.2633 
3 6 3 No. 6 0.349 8.87  2280 10.1  222.5  331.16 78732 39.89 56.70  10.65  0.3319 
3 7 3 No. 7 0.311 7.90  1809 8.0  176.6  262.75 62467 31.65 35.70  8.45  0.4184 
3 8 3 No. 8 0.277 7.03  1434 6.4  140.0  208.36 49537 25.1 22.45  6.70  0.5276 
3 9 3 No. 9 0.247 6.26  1137 5.1  111.0  165.14 39262 19.89 14.10  5.31  0.6657 
3 10 3 No. 10 0.22 5.58  902 4.0  88.0  131.02 31151 15.78 8.88  4.21  0.8390 
3 12 3 No. 12 0.174 4.42  567 2.5  55.4  82.38 19586 9.92 3.51  2.65  1.3344 
7 4 7 No. 4 0.613 15.57  8015 35.7  827.4  1231.34 292169 148.04 780.87  39.52  0.0896 
7 5 7 No. 5 0.546 13.86  6354 28.3  655.9  976.13 231613 117.36 490.72  31.33  0.1131 
7 6 7 No. 6 0.486 12.34  5040 22.4  520.2  774.23 183708 93.09 308.72  24.85  0.1425 
7 7 7 No. 7 0.433 11.00  3998 17.8  412.8  614.29 145757 73.86 194.34  19.72  0.1797 
7 8 7 No. 8 0.386 9.79  3171 14.1  327.3  487.13 115586 58.57 122.21  15.63  0.2266 
7 9 7 No. 9 0.343 8.72  2513 11.2  259.4  386.09 91612 46.42 76.77  12.39  0.2858 
7 10 7 No. 10 0.306 7.76  1994 8.9  205.8  306.33 72685 36.83 48.33  9.83  0.3603 
19 5 19 No. 5 0.91 23.10  17246 76.7  1787.4  2659.98 628665 318.55 3615.33  85.03  0.0418 
19 6 19 No. 6 0.81 20.57  13679 60.8  1417.7  2109.81 498636 252.66 2274.45  67.45  0.0527 
19 7 19 No. 7 0.722 18.33  10853 48.3  1124.8  1673.96 395627 200.47 1431.80  53.51  0.0665 
19 8 19 No. 8 0.643 16.32  8606 38.3  892.0  1327.45 313733 158.97 900.39  42.44  0.0838 
19 9 19 No. 9 0.572 14.53  6821 30.3  707.0  1052.12 248660 126 565.62  33.63  0.1057 
19 -   0.528 13.40  5801 25.8  601.2  894.78 211475 107.16 409.10  28.60  0.1243 
19 10 19 No. 10 0.51 12.94  5412 24.1  560.9  834.76 197289 99.97 356.05  26.69  0.1333 
7 - 2/0 0.414 10.51  3652 16.2  377.0  561.01 133115 67.45 162.09  18.01  0.1967 
 
TESTING
  

HENAN UME CABLE CO., LTD has a strict quality control policy in every step from the order to After-sales service!

 

     Production:

  • Raw material inspection and test
  • Production process test
  • Unqualified product control
  • Regular test and examination
  • Finished product inspection
Copper Clad Steel Wire High Conductivity Overhead Transmission Lines CCS

 

Certifications
UME CABLE has completed several third-party product certifications to ensure our customers that all of the wire and cable purchased and installed in your projects, will fully and consistently meet all criteria of the required production and performance standards, also you are guaranteed we (as the manufacturer) and the products supplied are both valid and continuously monitored by those globally recognized quality verification system listed as below: ISO9001, ISO14001, ISO45001, CE, SGS, TUV.
Copper Clad Steel Wire High Conductivity Overhead Transmission Lines CCS


 

Packaging & Shipping

 

Copper Clad Steel Wire High Conductivity Overhead Transmission Lines CCS
Copper Clad Steel Wire High Conductivity Overhead Transmission Lines CCS


 
Customer Visit

Copper Clad Steel Wire High Conductivity Overhead Transmission Lines CCS

 
Company Profile
Copper Clad Steel Wire High Conductivity Overhead Transmission Lines CCS
UME CABLE is one of the leading companies in the production and distribution of cables and wires in China. As a manufacturer, we have supplied quality products to more than 50 countries. Our mission is to offer our customers the best quality cable and wire products at the most competitive price, to extend and zoom the business success of our partners, to make power reach where it is needed, to optimize the running utility grids, and ultimately, to power the world. Our version is to be the most customer-centric cable and wire company with our solid technology, enthusiastic services, and robust products.

UME Cable was founded in 1994, located in Zhengzhou Gongyi Huiguo Town, and occupies a total area of more than 200,000 square meters, with a building area of 20,000 square meters. The real capital assets are more than USD 6 million, with a total of 230 staff members, 35 of which are professional and technical experts. The land of our factory and employees numbers might not be the top scale of industry, but our highly automatic facilities and elite employees are the best in the industry will guarantee you a high yield rate achieved by strict cost and quality control, this is why we could quote better quality with the most competitive price within the market.

 

FAQ

Q1: Are you a manufacturer?
Yes, we are the manufacturer.

Q2: What are your main products?
  Our products range as follows:
1. Electrical wire/PVC Building Wires.
2. PVC/XLPE insulated Power Cables up to 110kv.
3. Overhead Aerial Bundle Cable/ABC Cables.                                                                                                       
4. Bare Conductors, like AAC, AAAC, ACSR, ACAR, ASCR/AW, and so on.
5. Steel wire/strand-like EHS, GSW and ACS(Aluminum Clad Steel), CCS(Copper Clad Steel).
6. Rubber Cables, Mining Cables, Welding Cable, and Control Cables.
7. Concentric Cables with Copper/Aluminum/Aluminum Alloy 8000s' Conductor.

Q3: Do you provide samples? Is it free or extra?
  Yes, we could offer the samples for free

Q4: Is the quality of your products guaranteed?
  We have passed ISO9001, ISO14001, ISO45001, and all our products have CE certificates.

Q5: Which markets do you involve mainly in?
Our products have been exported mainly to Africa, the Middle East, Southeast Asia, South America, Central America, North America, Europe, Australia, etc.

Q6: What is your payment term?
  T/T or L/C

Q7: What about the delivery time?
Generally, it is 3-7days if the goods are in stock. Or it is 7-30days if the goods are not in stock, it is according to quantity.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier