Type: | Insulated |
---|---|
Conductor Type: | Solid Strand |
Application: | Overhead |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ONE-STOP SOLUTIONS FOR WIRES&CABLES - HENAN UME CABLE CO., LTD
Over 30 years of Wires and Cables manufacture experience and Export to over 50 countries.
1. Applications
0.6/1kv CAAI cable also called insulated ABC Cable usually used for urban and rural overhead secondary distribution networks, with voltages up to 1000 V.
2. Construction
1. Conductor: Aluminium 1350, class 2.
2. Insulation: Cross linked polyethylene XLPE.
3. Public lighting: Aluminium 1350 insulated with cross-linked polyethylene XLPE.
4. Insulated neutral messenger: AAAC - All Alloy Aluminium 6201 - XLPE.
5. Core identification: rib markings
3. Standard
IEC, ASTM, ICEA S-76-474
Code Word | 3×25mm2+1×54.6mm2 | 3×35mm2+1×54.6mm2 | 3×50mm2+1×54.6mm2 | 3×70mm2+1×54.6mm2 | 3×35mm2+1×54.6mm2+1×16mm2 | 3×70mm2+1×54.6mm2+1×16mm2 | 3×70+1×70mm2 | ||
Phase Conductor | Cross Section (mm) | 25 | 35 | 50 | 70 | 35 | 70 | 70 | |
Number of Wires | 7 | 7 | 7 | 12 | 7 | 12 | 12 | ||
Insulation Thickness (mm) | 1.4 | 1.6 | 1.6 | 1.8 | 1.6 | 1.8 | 1.8 | ||
D.C.Resistance At 20 ºC(Ohm/km) | 1.2 | 0.868 | 0.641 | 0.443 | 0.868 | 0.443 | 0.443 | ||
Minium Rated Strength(daN) | 300 | - | - | - | - | - | - | ||
Messenger | Cross Section (mm) | 54.6 | 54.6 | 54.6 | 54.6 | 54.6 | 54.6 | 70 | |
Number of Wires | 7 | 7 | 7 | 7 | 7 | 7 | 7 | ||
Insulation Thickness (mm) | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.5 | ||
D.C.Resistance A 20 ºC( Ohm/km) | 0.63 | 0.63 | 0.63 | 0.63 | 0.63 | 0.63 | 0.5 | ||
Minium Rated Strength(daN) | 1660 | 1660 | 1660 | 1660 | 1660 | 1660 | 2050 | ||
Public Lighting | Cross Section (mm) | - | - | - | - | 16 | 16 | - | |
Number of Wires | - | - | - | - | 7 | 7 | - | ||
Insulation Thickness (mm) | - | - | - | - | 1.2 | 1.2 | - | ||
D.C.Resistance At 20 ºC(Ohm/km) | - | - | - | - | 1.91 | 1.91 | - | ||
Minium Rated Strength(daN) | - | - | - | - | 190 | 190 | - | ||
Conductor Diameter | Phase | Max | 6.3 | 7.3 | 8.4 | 10.2 | 7.3 | 10.2 | 10.2 |
Min | 5.8 | 6.8 | 7.9 | 9.7 | 6.8 | 9.7 | 9.7 | ||
Messenger | Max | - | - | - | - | 5.1 | 5.1 | - | |
Min | - | - | - | - | 4.6 | 4.6 | - | ||
Public Lighting | Max | - | - | - | - | 5.1 | 5.1 | - | |
Min | - | - | - | - | 4.6 | 4.6 | - | ||
Overall Diameter | Phase | Max | 9.4 | 10.9 | 12 | 14.2 | 10.9 | 14.2 | 14.2 |
Min | 8.6 | 10 | 11.1 | 13.3 | 10 | 13.3 | 13.3 | ||
Messenger | Max | 13 | 13 | 13 | 13 | 13 | 13 | 13.6 | |
Min | 12.3 | 12.3 | 12.3 | 12.3 | 12.3 | 12.3 | 12.9 | ||
Public Lighting | Max | - | - | - | - | 7.8 | 7.8 | - | |
Min | - | - | - | - | 7 | 7 | - |
Code Word | 3×70mm2+1×16mm2 | 3×95mm2+1×70mm2 | 3×95mm2+ 1×70+ 1×16mm2 | 3×120mm2+1×70mm2 | 3×120mm2+1×70+1×16mm2 | 3×150mm2+1×70mm2 | 3×70mm2+1×70mm2+1×16mm2 | ||
Phase Conductor | Cross Section (mm) | 70 | 95 | 95 | 120 | 120 | 150 | 150 | |
Number of Wires | 12 | 19 | 19 | 19 | 19 | 19 | 19 | ||
Insulation Thickness (mm) | 1.8 | 1.8 | 1.8 | 1.8 | 1.8 | 1.7 | 1.7 | ||
D.C.Resistance At 20 ºC( Ohm/km) | 0.443 | 0.32 | 0.32 | 0.253 | 0.253 | 0.206 | 0.206 | ||
Minium Rated Strength(daN) | - | - | - | - | - | - | - | ||
Messenger | Cross Section (mm) | 70 | 70 | 70 | 70 | 70 | 70 | 70 | |
Number of Wires | 7 | 7 | 7 | 7 | 7 | 7 | 7 | ||
Insulation Thickness (mm) | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | ||
D.C.Resistance At 20 ºC( Ohm/km) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | ||
Minium Rated Strength(daN) | 2050 | 2050 | 2050 | 2050 | 2050 | 2050 | 2050 | ||
Public Lighting | Cross Section (mm) | 16 | - | 16 | - | 16 | - | 16 | |
Number of Wires | 7 | - | 7 | - | 7 | - | 7 | ||
Insulation Thickness (mm) | 1.2 | - | 1.2 | - | 1.2 | - | 1.2 | ||
D.C.Resistance At 20 ºC( Ohm/km) | 1.91 | - | 1.91 | - | 1.91 | - | 1.91 | ||
Minium Rated Strength(daN) | 190 | - | 190 | - | 190 | - | 190 | ||
Conductor Diameter | Phase | Max | 10.2 | 12 | 12 | 13.1 | 13.1 | 15 | 15 |
Min | 9.7 | 11 | 11 | 12 | 12 | 13.9 | 13.9 | ||
Messenger | Max | 10.2 | 10.2 | 10.2 | 10.2 | 10.2 | 10.2 | 10.2 | |
Min | 10 | 10 | 10 | 10 | 10 | 10 | 10 | ||
Public Lighting | Max | 5.1 | - | 5.1 | - | 5.1 | 5.1 | 5.1 | |
Min | 4.6 | - | 4.6 | - | 4.6 | 4.6 | 4.6 | ||
Overall Diameter | Phase | Max | 14.2 | 15.7 | 15.7 | 16.7 | 16.7 | 18.6 | |
Min | 13.3 | 14.6 | 14.6 | 15.6 | 15.6 | 17.3 | |||
Messenger | Max | 13.6 | 13.6 | 13.6 | 13.6 | 13.6 | 13.6 | ||
Min | 12.9 | 12.9 | 12.9 | 12.9 | 12.9 | 12.9 | |||
Public Lighting | Max | 7.8 | - | 7.8 | 7.8 | 7.8 | 7.8 | ||
Min | 7 | - | 7 | 7 | 7 | 7 |
HENAN UME CABLE CO., LTD has a strict quality control policy in every step from the order to After-sales service!
Production:
Q1: Are you a manufacturer?
Yes, we are the manufacturer.
Q2: What are your main products?
Our products range as follows:
1. Electrical wire/PVC Building Wires.
2. PVC/XLPE insulated Power Cables up to 110kv.
3. Overhead Aerial Bundle Cable/ABC Cables.
4. Bare Conductors, like AAC, AAAC, ACSR, ACAR, ASCR/AW, and so on.
5. Steel wire/strand-like EHS, GSW and ACS(Aluminum Clad Steel), CCS(Copper Clad Steel).
6. Rubber Cables, Mining Cables, Welding Cable, and Control Cables.
7. Concentric Cables with Copper/Aluminum/Aluminum Alloy 8000s' Conductor.
Q3: Do you provide samples? Is it free or extra?
Yes, we could offer the samples for free
Q4: Is the quality of your products guaranteed?
We have passed ISO9001, ISO14001, ISO45001, and all our products have CE certificates.
Q5: Which markets do you involve mainly in?
Our products have been exported mainly to Africa, the Middle East, Southeast Asia, South America, Central America, North America, Europe, Australia, etc.
Q6: What is your payment term?
T/T or L/C
Q7: What about the delivery time?
Generally, it is 3-7days if the goods are in stock. Or it is 7-30days if the goods are not in stock, it is according to quantity.