Type: | Bare |
---|---|
Conductor Type: | Stranded |
Application: | Overhead |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ONE-STOP SOLUTIONS FOR WIRES&CABLES - HENAN UME CABLE CO., LTD
Over 30 years of Wires and Cables manufacture experience and Export to over 50 countries.
1. Applications
AAAC is used as a bare overhead conductor for power transmission and distribution line, on aerial circuits that require a larger mechanical resistance than AAC, and a better corrosion resistance than ACSR.
2. Construction
AAAC is concentric-lay- stranded, similar in construction and appearance with1350 grade aluminum conductors.
3. Standards
IEC 61089, DIN 48201, ASTM B399
Code Name |
Nominal Area |
No. / Dia. of Wire | Approx. Overall Dia. |
Approx. Weight |
Calculated Breaking Load |
Max. DC Resistance at 20° C |
mm2 | No./mm | mm | kg/km | kN | Ω/km | |
16 | 18.4 | 7/1.83 | 5.49 | 50.4 | 5.4 | 1.7896 |
25 | 28.8 | 7/2.29 | 6.87 | 78.7 | 8.5 | 1.1453 |
40 | 46 | 7/2.89 | 8.67 | 125.9 | 13.6 | 0.7158 |
63 | 72.5 | 7/3.63 | 10.89 | 198.3 | 21.4 | 0.4545 |
100 | 115 | 19/2.78 | 13.90 | 316.3 | 34.0 | 0.2877 |
125 | 144 | 19/3.10 | 15.50 | 395.4 | 42.4 | 0.2302 |
160 | 184 | 19/3.51 | 17.55 | 506.1 | 54.3 | 0.1798 |
200 | 230 | 19/3.93 | 19.65 | 632.7 | 67.9 | 0.1439 |
250 | 288 | 19/4.39 | 21.95 | 790.8 | 84.9 | 0.1151 |
315 | 363 | 37/3.53 | 24.71 | 998.9 | 107.0 | 0.0916 |
400 | 460 | 37/3.98 | 27.86 | 1268.4 | 135.8 | 0.0721 |
450 | 518 | 37/4.22 | 29.54 | 1426.9 | 152.8 | 0.0641 |
500 | 575 | 37/4.45 | 31.15 | 1585.5 | 169.8 | 0.0577 |
560 | 645 | 61/3.67 | 33.03 | 1778.4 | 190.1 | 0.0516 |
630 | 725 | 61/3.89 | 35.01 | 2000.7 | 213.9 | 0.0458 |
710 | 817 | 61/4.13 | 37.17 | 2254.8 | 241.1 | 0.0407 |
800 | 921 | 61/4.38 | 39.42 | 2540.6 | 271.6 | 0.0361 |
900 | 1036 | 91/3.81 | 41.91 | 2861.1 | 305.6 | 0.0321 |
1000 | 1151 | 91/4.01 | 44.11 | 3179.0 | 339.5 | 0.0289 |
1120 | 1289 | 91/4.25 | 46.75 | 3560.5 | 380.3 | 0.0258 |
1250 | 1439 | 91/4.49 | 49.39 | 3973.7 | 424.4 | 0.0231 |
Nominal Area |
Actual Area |
No. / Dia. of Wire | Approx. Overall Dia. |
Approx. Weight |
Calculated Breaking Load |
Max. DC Resistance at 20° C |
mm2 | mm2 | No./mm | mm | kg/km | kN | Ω/km |
16 | 15.9 | 7/1.70 | 5.1 | 43 | 4.4 | 2.0742 |
25 | 24.3 | 7/2.10 | 6.3 | 66 | 6.8 | 1.3593 |
35 | 34.4 | 7/2.50 | 7.5 | 94 | 9.6 | 0.9591 |
50 | 49.5 | 7/3.00 | 9.0 | 135 | 13.8 | 0.6660 |
50 | 48.4 | 19/1.80 | 9.0 | 133 | 13.5 | 0.6849 |
70 | 65.8 | 19/2.10 | 10.5 | 181 | 18.4 | 0.5032 |
95 | 93.3 | 19/2.50 | 12.5 | 256 | 26.1 | 0.3551 |
120 | 117.0 | 19/2.80 | 14.0 | 322 | 32.7 | 0.2831 |
150 | 147.1 | 37/2.25 | 15.8 | 406 | 41.1 | 0.2256 |
185 | 181.6 | 37/2.50 | 17.5 | 500 | 50.7 | 0.1828 |
240 | 242.5 | 61/2.25 | 20.3 | 670 | 67.7 | 0.1371 |
300 | 299.4 | 61/2.50 | 22.5 | 827 | 83.6 | 0.1110 |
400 | 400.1 | 61/2.89 | 26.0 | 1104 | 111.8 | 0.0831 |
500 | 499.8 | 61/3.23 | 29.1 | 1379 | 139.6 | 0.0665 |
625 | 626.2 | 91/2.96 | 32.6 | 1732 | 174.9 | 0.0531 |
800 | 802.1 | 91/3.35 | 36.9 | 2218 | 224.0 | 0.0415 |
1000 | 999.7 | 91/3.74 | 41.1 | 2767 | 279.2 | 0.0333 |
Code Name |
Total Area | 1350 Grade Equivalent | No. / Dia. of Wire | Approx. Overall Dia. |
Approx. Weight |
Calculated Breaking Load |
Max. DC Resistance at 20° C |
|
AWG or MCM | mm2 | AWG or MCM | No./mm | mm | kg/km | kN | Ω/km | |
Akron | 30.6 | 15.5 | 6 | 7/1.68 | 5.04 | 43 | 4.9 | 2.1588 |
Alton | 48.7 | 24.7 | 4 | 7/2.12 | 6.36 | 68 | 7.8 | 1.3557 |
Ames | 77.5 | 39.2 | 2 | 7/2.67 | 8.01 | 108 | 12.4 | 0.8547 |
Azusa | 123.3 | 62.4 | 1 | 7/3.37 | 10.11 | 171 | 18.9 | 0.5365 |
Anaheim | 155.4 | 78.6 | 2/0 | 7/3.78 | 11.34 | 216 | 23.8 | 0.4264 |
Amherst | 195.7 | 99.3 | 3/0 | 7/4.25 | 12.75 | 272 | 30.0 | 0.3373 |
Alliance | 246.9 | 125.1 | 4/0 | 7/4.77 | 14.31 | 343 | 37.8 | 0.2678 |
Butte | 312.8 | 158.6 | 266.8 | 19/3.26 | 16.30 | 435 | 46.5 | 0.2112 |
Canton | 394.5 | 199.9 | 336.4 | 19/3.66 | 18.30 | 548 | 58.6 | 0.1676 |
Cairo | 465.4 | 236.4 | 397.5 | 19/3.98 | 19.90 | 649 | 69.3 | 0.1417 |
Darien | 559.5 | 283.6 | 477 | 19/4.36 | 21.80 | 778 | 83.1 | 0.1181 |
Elgin | 652.6 | 331.0 | 556.5 | 19/4.71 | 23.55 | 908 | 97.0 | 0.1012 |
Flint | 740.8 | 374.5 | 636 | 19/3.59 | 25.13 | 1028 | 107.4 | 0.0894 |
Greeley | 927.2 | 469.6 | 795 | 19/4.02 | 28.14 | 1289 | 134.6 | 0.0713 |
HENAN UME CABLE CO., LTD has a strict quality control policy in every step from the order to After-sales service!
Production:
Q1: Are you a manufacturer?
Yes, we are the manufacturer.
Q2: What are your main products?
Our products range as follows:
1. Electrical wire/PVC Building Wires.
2. PVC/XLPE insulated Power Cables up to 110kv.
3. Overhead Aerial Bundle Cable/ABC Cables.
4. Bare Conductors, like AAC, AAAC, ACSR, ACAR, ASCR/AW, and so on.
5. Steel wire/strand-like EHS, GSW and ACS(Aluminum Clad Steel), CCS(Copper Clad Steel).
6. Rubber Cables, Mining Cables, Welding Cable, and Control Cables.
7. Concentric Cables with Copper/Aluminum/Aluminum Alloy 8000s' Conductor.
Q3: Do you provide samples? Is it free or extra?
Yes, we could offer the samples for free
Q4: Is the quality of your products guaranteed?
We have passed ISO9001, ISO14001, ISO45001, and all our products have CE certificates.
Q5: Which markets do you involve mainly in?
Our products have been exported mainly to Africa, the Middle East, Southeast Asia, South America, Central America, North America, Europe, Australia, etc.
Q6: What is your payment term?
T/T or L/C
Q7: What about the delivery time?
Generally, it is 3-7days if the goods are in stock. Or it is 7-30days if the goods are not in stock, it is according to quantity.