Low Voltage Single Core Cable XLPE Underground Cable

Product Details
Type: Insulated
Conductor Type: Solid/Strand
Application: Overhead
Still deciding? Get samples of US$ 1/Piece
Request Sample
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Low Voltage Single Core Cable XLPE Underground Cable
  • Low Voltage Single Core Cable XLPE Underground Cable
  • Low Voltage Single Core Cable XLPE Underground Cable
  • Low Voltage Single Core Cable XLPE Underground Cable
  • Low Voltage Single Core Cable XLPE Underground Cable
  • Low Voltage Single Core Cable XLPE Underground Cable
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • TESTING
  • Certifications
  • Packaging & Shipping
  • Customer Visit
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
Underground Cable
Conductor Material
Copper/Aluminum
Sheath Material
PVC
Insulation Material
XLPE
Material Shape
Round Wire
Range of Application
Underground
Certification
ISO9001, CE
Brand
Ume
Third Party Inspection
Accepted
Sample
Free
Color
Customer Specified
OEM
Accepted
Transport Package
Drum
Specification
Underground Cable
Trademark
UME
Origin
China
HS Code
8544492100
Production Capacity
500, 000km Per Month

Product Description

Product Description

ONE-STOP SOLUTIONS FOR WIRES&CABLES - HENAN UME CABLE CO., LTD
Over 30 years of Wires and Cables manufacture experience and Export to over 50 countries.

Low Voltage Single Core Cable XLPE Underground Cable
Low Voltage Single Core Cable XLPE Underground Cable

1. Application
Power cable suitable for power networks, direct burial, outdoors, indoors and in cable ducts.

2. Construction

Conductors are stranded , compressed 1350-H19,H16 or H26 aluminum ,insulated with XLPE.

3. Standard

NF C 32-321 C32-321/A1; IEC 60502-1 NF EN 60332-1-2; NF C 15-100

Product Parameters
Single core
Cores
number
Cross
section
mm²
Approx
conductor
diameter
mm
Insulation
medium
thickness
mm
Min. sheath
thickness
mm
Max.
external
diameter
mm
Electric
resistance at
20°C
ohm/km
Approx
cable weight
kg/km
Current
carrying
air free
A
Current
carrying
burried
A
Single core
1x 1.5 1.4 0.7 1.09 6.6 12.1 45 24 31
1x 2.5 1.8 0.7 1.09 7 7.41 55 33 41
1x 4 2.25 0.7 1.09 7.6 4.61 75 45 59
1x 6 3.05 0.7 1.09 8.2 3.08 100 58 74
1x 10 3.8 0.7 1.09 9.2 1.83 140 80 101
1x 16 4.7 0.7 1.09 10.5 1.15 205 107 128
1x 25 5.9 0.9 1.09 12.5 0.727 315 138 144
1x 35 7.1 0.9 1.09 13.5 0.524 400 169 174
1x 50 8 1 1.09 15 0.387 530 207 206
1x 70 9.6 1.1 1.09 17 0.268 725 268 254
1x 95 11.4 1.1 1.18 19 0.193 985 328 301
1x 120 13.1 1.2 1.18 21 0.153 1260 382 343
1x 150 14.6 1.4 1.26 23 0.124 1520 441 387
1x 185 16.5 1.6 1.26 25.5 0.0991 1940 506 434
1x 240 18.4 1.7 1.35 28.5 0.0754 2310 599 501
1x 300 21.1 1.8 1.43 31 0.0601 3200 693 565
1x 400 23.5 2 1.52 34.2 0.047 3931 - 639
1x 500 26.5 2.2 1.6 38 0.0366 5020 - 713
1x 630 30.1 2.4 1.69 44 0.0286 5324 - 785
2 cores

Size

Sq.mm

Class

Of

conductor

Max. diameter over conductor mm

insulation Thickness

Diameter over core mm

bedding
mm

Diameter over bedding mm

Diameter of armour wire

mm

Diameter over armour mm

Approx overall diameter

mm

Weight kg/km

1.5

2

1.59

0.6

3.0

0.8

7.7

0.9

9.6

12.3

300

2.5

2

2.01

0.7

3.4

0.8

8.5

0.9

10.4

13.6

360

4

2

2.55

0.7

4.0

0.8

9.7

0.9

11.6

14.7

420

6

2

3.12

0.7

4.5

0.8

10.7

0.9

12.6

15.9

500

10

2

4.05

0.7

5.5

0.8

12.7

0.9

14.6

18.0

650

16

2

5.10

0.7

6.5

0.8

14.5

1.25

17.0

20.0

910

25

2*

-

0.9

-

0.8

18.4

1.25

20.9

24.1

1060

35

2*

-

0.9

-

1.0

21.3

1.6

24.5

27.9

1480

50

2S

-

1.0

-

1.0

19.0

1.6

22.2

25.8

1800

70

2S

-

1.1

-

1.0

22.0

1.6

25.2

29.0

2300

95

2S

-

1.1

-

1.2

25.1

2.0

29.1

33.1

3170

120

2S

-

1.2

-

1.2

27.9

2.0

31.9

36.1

3800

150

2S

-

1.4

-

1.2

30.9

2.0

34.9

39.3

4500

185

2S

-

1.6

-

1.4

34.9

2.5

39.9

44.7

5800

240

2S

-

1.7

-

1.4

39.0

2.5

44.0

59.0

7280

300

2S

-

1.8

-

1.6

43.3

2.5

48.3

53.5

8750

400

2S

-

2.0

-

1.6

48.4

2.5

53.4

59.0

10700

3 cores

Size

Sq.mm

Class of conductor

bedding

mm

Diameter over bedding

mm

Diameter of armour wire

mm

Diameter over armour

mm

Approx overall diameter

mm

Weight

kg/km

1.5

2

0.8

8.2

0.9

10.1

12.8

341

2.5

2

0.8

9.1

0.9

11.0

14.1

405

4

2

0.8

10.4

0.9

12.3

15.3

495

6

2

0.8

11.5

0.9

13.4

16.6

600

10

2

0.8

13.7

1.25

16.4

19.5

900

16

2

0.8

15.5

1.25

18.0

21.2

1080

25

2*

1.0

20.1

1.6

23.3

26.7

1750

35

2*

1.0

22.8

1.6

26.0

29.6

2100

50

2S

1.0

21.7

1.6

24.9

28.5

2350

70

2S

1.0

25.2

1.6

28.4

32.2

3150

95

2S

1.2

28.8

2.0

32.8

37.0

4300

120

2S

1.2

32.0

2.0

36.0

40.4

5250

150

2S

1.4

35.9

2.5

40.9

45.5

6720

185

2S

1.4

40.0

2.5

45.0

49.8

8040

240

2S

1.4

44.9

2.5

49.9

55.1

10150

300

2S

1.6

49.8

2.5

54.8

60.2

12320

400

2S

1.6

55.4

2.5

60.6

66.6

15090

4 cores

Size

Sq.mm

Class of conductor

bedding

mm

Diameter over bedding

mm

Diameter of armour wire

mm

Diameter over armour

mm

Approx overall diameter

mm

Weight

kg/km

1.5

2

0.8

9.0

0.9

10.9

13.5

390

2.5

2

0.8

10.0

0.9

11.9

15.0

465

4

2

0.8

11.5

0.9

13.4

16.4

579

6

2

0.8

12.7

0.9

15.3

18.7

820

10

2

0.8

15.1

1.25

17.6

21.1

1090

16

2

0.8

17.2

1.25

19.7

22.9

1400

25

2*

1.0

22.3

1.6

25.5

28.9

2100

35

2*

1.0

25.3

1.6

28.5

32.1

2580

50

2S

1.0

25.0

1.6

28.2

32.0

3000

70

2S

1.2

29.5

2.0

33.5

37.7

4300

95

2S

1.2

33.3

2.0

37.3

41.7

5510

120

2S

1.4

37.5

2.0

42.5

47.1

7150

150

2S

1.4

41.6

2.5

46.6

51.4

8500

185

2S

1.4

46.4

2.5

51.4

56.6

10300

240

2S

1.6

52.6

2.5

57.6

63.0

13000

300

2S

1.6

58.0

2.5

63.0

68.8

15750

400

2S

1.8

64.8

3.15

71.3

78.1

20450

5 cores

Size

Sq.mm

Class of conductor

bedding

mm

Diameter over bedding

mm

Diameter of armour wire

mm

Diameter over armour

mm

Approx overall diameter

mm

Weight

kg/km

1.5

2

0.8

9.9

0.9

11.8

14.2

433

2.5

2

0.8

11.0

0.9

12.9

16.0

530

4

2

0.8

12.7

1.25

15.3

18.4

775

6

2

0.8

14.0

1.25

16.6

19.7

929

10

2

1.0

17.1

1.25

19.7

23.2

1300

16

2

1.0

19.8

1.6

23.1

26.6

1880

25

2

1.0

24.5

1.6

27.8

31.7

2670

35

2

1.0

25.5

1.6

28.7

33.0

2800

50

-

-

-

-

-

-

-

70

-

-

-

-

-

-

-

95

-

-

-

-

-

-

-

6 cores

Size

Sq.mm

Class of conductor

bedding

mm

Diameter over bedding

mm

Diameter of armour wire

mm

Diameter over armour

mm

Approx overall diameter

mm

Weight

kg/km

1.5

2

0.8

10.9

0.9

12.8

15.2

497

2.5

2

0.8

12.1

0.9

14.0

17.1

609

4

2

0.8

13.9

0.9

16.5

19.7

886

6

2

0.8

15.4

1.25

18.0

21.3

1070

10

2

1.0

18.8

1.6

22.1

25.6

1650

16

2

1.0

21.8

1.6

25.1

28.8

2190

25

2

1.0

26.9

1.6

30.2

34.1

3090

7 cores

Size

Sq.mm

Class of conductor

bedding

mm

Diameter over bedding

mm

Diameter of armour wire

mm

Diameter over armour

mm

Approx overall diameter

mm

Weight

kg/km

1.5

2

0.8

10.9

0.9

12.8

15.2

506

2.5

2

0.8

12.1

0.9

14.0

17.1

618

4

2

0.8

13.9

1.25

16.5

19.7

907

6

2

0.8

15.4

1.25

18.0

21.3

1110

10

2

1.0

18.8

1.25

22.1

25.6

1720

16

2

1.0

21.8

1.6

25.1

28.8

2300

25

2

1.0

30.2

1.6

34.3

38.6

3900

8 cores

Size

Sq.mm

Class of conductor

bedding

mm

Diameter over bedding

mm

Diameter of armour wire

mm

Diameter over armour

mm

Approx overall diameter

mm

Weight

kg/km

1.5

2

0.8

11.9

1.25

14.5

17.6

663

2.5

2

0.8

13.1

1.25

15.7

18.8

793

4

2

0.8

15.3

1.25

17.9

21.2

1030

6

2

1.0

17.3

1.6

20.6

24.1

1440

10

2

1.0

20.7

1.6

24.0

27.7

1960

10 cores

Size

Sq.mm

Class of conductor

bedding

mm

Diameter over bedding

mm

Diameter of armour wire

mm

Diameter over armour

mm

Approx overall diameter

mm

Weight

kg/km

1.5

2

0.8

13.9

1.25

16.5

19.8

812

2.5

2

0.8

15.5

1.25

18.1

21.4

989

4

2

1.0

18.3

1.6

21.6

25.1

1410

6

2

1.0

20.3

1.6

23.6

27.3

1680

10

2

1.0

24.3

1.6

27.6

31.5

2320

12 cores

Size

Sq.mm

Class of conductor

bedding

mm

Diameter over bedding

mm

Diameter of armour wire

mm

Diameter over armour

mm

Approx overall diameter

mm

Weight

kg/km

1.5

2

0.8

14.3

1.25

16.9

19.4

854

2.5

2

0.8

16.0

1.25

18.6

22.4

1080

4

2

1.0

18.9

1.6

22.2

27.7

1550

6

2

1.0

21.0

1.6

24.3

28.0

1920

10

2

1.0

25.1

1.6

28.4

32.3

2660

16 cores

Size

Sq.mm

Class of conductor

bedding mm

Diameter over bedding

mm

Diameter of armour wire

mm

Diameter over armour

mm

Approx overall diameter

mm

Weight

kg/km

1.5

2

0.8

16.0

1.25

18.6

21.9

1020

2.5

2

0.8

18.2

1.6

21.5

25.0

1430

4

2

1.0

22.1

1.6

25.4

29.1

1950

6

2

1.0

23.4

1.6

26.7

30.4

2300

 
TESTING

 

HENAN UME CABLE CO., LTD has a strict quality control policy in every step from the order to After-sales service!

 

     Production:

  • Raw material inspection and test
  • Production process test
  • Unqualified product control
  • Regular test and examination
  • Finished product inspection
Low Voltage Single Core Cable XLPE Underground Cable

 

Certifications
UME CABLE has completed several third-party product certifications to ensure our customers that all of the wire and cable purchased and installed in your projects, will fully and consistently meet all criteria of the required production and performance standards, also you are guaranteed we (as the manufacturer) and the products supplied are both valid and continuously monitored by those globally recognized quality verification system listed as below: ISO9001, ISO14001, ISO45001, CE, SGS, TUV.
Low Voltage Single Core Cable XLPE Underground Cable

 

Packaging & Shipping

 

Low Voltage Single Core Cable XLPE Underground Cable
Low Voltage Single Core Cable XLPE Underground Cable
Customer Visit

Low Voltage Single Core Cable XLPE Underground Cable

Company Profile
Low Voltage Single Core Cable XLPE Underground Cable
UME CABLE is one of the leading companies in the production and distribution of cables and wires in China. As a manufacturer, we have supplied quality products to more than 50 countries. Our mission is to offer our customers the best quality cable and wire products at the most competitive price, to extend and zoom the business success of our partners, to make power reach where it is needed, to optimize the running utility grids, and ultimately, to power the world. Our version is to be the most customer-centric cable and wire company with our solid technology, enthusiastic services, and robust products.

UME Cable was founded in 1994, located in Zhengzhou Gongyi Huiguo Town, and occupies a total area of more than 200,000 square meters, with a building area of 20,000 square meters. The real capital assets are more than USD 6 million, with a total of 230 staff members, 35 of which are professional and technical experts. The land of our factory and employees numbers might not be the top scale of industry, but our highly automatic facilities and elite employees are the best in the industry will guarantee you a high yield rate achieved by strict cost and quality control, this is why we could quote better quality with the most competitive price within the market.

 

FAQ

Q1: Are you a manufacturer?
Yes, we are the manufacturer.

Q2: What are your main products?
  Our products range as follows:
1. Electrical wire/PVC Building Wires.
2. PVC/XLPE insulated Power Cables up to 110kv.
3. Overhead Aerial Bundle Cable/ABC Cables.                                                                                                       
4. Bare Conductors, like AAC, AAAC, ACSR, ACAR, ASCR/AW, and so on.
5. Steel wire/strand-like EHS, GSW and ACS(Aluminum Clad Steel), CCS(Copper Clad Steel).
6. Rubber Cables, Mining Cables, Welding Cable, and Control Cables.
7. Concentric Cables with Copper/Aluminum/Aluminum Alloy 8000s' Conductor.

Q3: Do you provide samples? Is it free or extra?
  Yes, we could offer the samples for free

Q4: Is the quality of your products guaranteed?
  We have passed ISO9001, ISO14001, ISO45001, and all our products have CE certificates.

Q5: Which markets do you involve mainly in?
Our products have been exported mainly to Africa, the Middle East, Southeast Asia, South America, Central America, North America, Europe, Australia, etc.

Q6: What is your payment term?
  T/T or L/C

Q7: What about the delivery time?
Generally, it is 3-7days if the goods are in stock. Or it is 7-30days if the goods are not in stock, it is according to quantity.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now