Type: | Insulated |
---|---|
Conductor Type: | Solid Strand Flexible |
Application: | Underground, Building Householding |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ONE-STOP SOLUTIONS FOR WIRES&CABLES - HENAN UME CABLE CO., LTD
Over 30 years of Wires and Cables manufacture experience and Export to over 50 countries.
1. Applications
H05V-K cable is used for the internal wiring of electric motors and transformers as well as other electrical appliances and lighting applications. It can be used in and at electronic appliances for measuring, regulating and controlling. The cables are also ideal for laying in pipes, surface wiring and conduit installations. Specifications according to HD 516 apply for respective specific applications.
H05V-U cable is intended for the installation to the inside of apparatus as well as for the protective laying to the lightings, in dry rooms, in production facilities, switch and distributor boards, in tubes, under and surface mounting of plasters.
H05V-R is preferably for installation indoors, in cable ducts and in industrial plants or switching stations, under ground installation. Can be used in switchboards and distributor boards or where a thicker strand of multi-wire is required.Found in electronic and electrical equipment and switchgear cabinets designed for export to a European country and for MRO replacement of European made equipment wire.
2. Construction
Conductor: Copper Conductor
Solid H05V-U class 1
Stranded H05V-R class 2
Flexible H05V-K class 5
3. Standard
H05V-R H05V-K H05V-K
H05V-U
No. | No. of Cores x | Nominal Overall | Nominal |
Size | Nominal Cross Sectional Area | Diameter | Copper |
AWG | mm² | mm | Weight kg/Km |
20 | 1 x 0.5 | 2.1 | 4.8 |
18 | 1 x 0.75 | 2.2 | 7.2 |
17 | 1 x 1 | 2.4 | 9.6 |
16 | 1 x 1.5 | 2.9 | 14.4 |
14 | 1 x 2.5 | 3.5 | 24 |
12 | 1 x 4 | 3.9 | 38 |
10 | 1 x 6 | 4.5 | 58 |
8 | 1 x 10 | 5.7 | 96 |
construction n x mm2 | outer diameter cca. mm | Cu Weight kg / km | Cable Weight cca. kg / km |
1 x 1.5 | 3 | 14,4 | 20 |
1 x 2.5 | 3,6 | 24 | 30 |
1 x 4 | 4,1 | 38 | 50 |
1 x 6 | 4,6 | 58 | 65 |
1 x 10 | 6 | 96 | 110 |
1 x 16 | 7 | 154 | 165 |
1 x 25 | 8,5 | 240 | 242 |
1 x 35 | 9,9 | 336 | 350 |
1 x 50 | 11,7 | 480 | 482 |
1 x 70 | 11,7 | 672 | 662 |
1 x 95 | 15,3 | 912 | 885 |
AWG | No. of Cores x Nominal Cross Sectional Area | Nominal Thickness of Insulation | Nominal Overall Diameter | Nominal Copper Weight | Nominal Weight |
x mm² | mm | mm | kg/km | kg/km | |
H05V-R | |||||
20(7/29) | 1 x 0.5 | 0.6 | 2.2 | 4.8 | 9 |
18(7/27) | 1 x 0.75 | 0.6 | 2.4 | 7.2 | 12 |
17(7/26) | 1 x 1 | 0.6 | 2.6 | 9.6 | 15 |
H07V-R H07V-U H05V-R H05V-U BY 227IEC01/05 equivalent to VDE 0281 BS6004 | |||||
Cross Section (mm2) |
Conductor Construction (No/mm) |
Insulation Thickness (mm) |
Overall Diameter Max (mm) |
Min Insulation Resistance@ 70ºC (ohm/Km) |
Weight Approx (Kg/Km) |
1x0.5 | 1/0.80 | 0.6 | 2.4 | 0.015 | 8 |
1x0.75 | 7/0.97 | 0.6 | 2.8 | 0.012 | 11 |
1x0.75 | 1/0.97 | 0.6 | 2.6 | 0.012 | 11 |
1x1.0 | 7/0.43 | 0.6 | 3.0 | / | 14 |
1x1.0 | 1/1.13 | 0.6 | 2.8 | 0.011 | 14 |
1x1.5 | 7/0.52 | 0.7 | 3.4 | 0.010 | 21 |
1x1.5 | 1x1.38 | 0.7 | 3.3 | 0.011 | 20 |
1x2.5 | 7/0.67 | 0.8 | 4.2 | 0.009 | 32 |
1x2.5 | 1x1.78 | 0.8 | 3.9 | 0.010 | 31 |
1x4 | 7/0.85 | 0.8 | 4.8 | 0.0077 | 45 |
1x4 | 1/2.25 | 0.8 | 4.4 | 0.0085 | 45 |
1x6 | 7/1.04 | 0.8 | 5.4 | 0.0065 | 65 |
1x6 | 1/2.76 | 0.8 | 4.9 | 0.0070 | 65 |
1x10 | 7/1.35 | 1.0 | 6.8 | 0.0065 | 110 |
1x10 | 1/3.57 | 1.0 | 6.4 | 0.0070 | 110 |
1x16 | 7/1.70 | 1.0 | 8.0 | 0.0050 | 165 |
1x25 | 7/2.14 | 1.2 | 9.8 | 0.0050 | 264 |
1x35 | 7/2.52 | 1.2 | 11.0 | 0.0040 | 360 |
1x50 | 19/1.78 | 1.4 | 13.0 | 0.0045 | 490 |
1x70 | 19/2.14 | 1.4 | 15.0 | 0.0035 | 685 |
1x95 | 19/2.52 | 1.6 | 17.5 | 0.0035 | 946 |
1x120 | 37/2.03 | 1.6 | 19.0 | 0.0032 | 1181 |
1x150 | 37/2.25 | 1.8 | 21.0 | 0.0032 | 1453 |
1x185 | 37/2.52 | 2.0 | 23.5 | 0.0032 | 1821 |
1x240 | 61/2.24 | 2.2 | 26.5 | 0.0032 | 2383 |
1x300 | 61/2.50 | 2.4 | 29.5 | 0.0030 | 2983 |
1x400 | 61/2.85 | 2.6 | 33.5 | 0.0028 | 3800 |
HENAN UME CABLE CO., LTD has a strict quality control policy in every step from the order to After-sales service!
Production:
Q1: Are you a manufacturer?
Yes, we are the manufacturer.
Q2: What are your main products?
Our products range as follows:
1. Electrical wire/PVC Building Wires.
2. PVC/XLPE insulated Power Cables up to 110kv.
3. Overhead Aerial Bundle Cable/ABC Cables.
4. Bare Conductors, like AAC, AAAC, ACSR, ACAR, ASCR/AW, and so on.
5. Steel wire/strand-like EHS, GSW and ACS(Aluminum Clad Steel), CCS(Copper Clad Steel).
6. Rubber Cables, Mining Cables, Welding Cable, and Control Cables.
7. Concentric Cables with Copper/Aluminum/Aluminum Alloy 8000s' Conductor.
Q3: Do you provide samples? Is it free or extra?
Yes, we could offer the samples for free
Q4: Is the quality of your products guaranteed?
We have passed ISO9001, ISO14001, ISO45001, and all our products have CE certificates.
Q5: Which markets do you involve mainly in?
Our products have been exported mainly to Africa, the Middle East, Southeast Asia, South America, Central America, North America, Europe, Australia, etc.
Q6: What is your payment term?
T/T or L/C
Q7: What about the delivery time?
Generally, it is 3-7days if the goods are in stock. Or it is 7-30days if the goods are not in stock, it is according to quantity.